Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single …24SCA4. Up to 16 SEER2 for moderate energy savings with standard comfort features. 4.4 out of 5 stars. 18 Reviews. 5 Star. 67%. 4 Star. 22%. 3 Star.Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ... 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger 38AU Gemini™ Commercial Split-System Air-Cooled Condensing Units & 40RU Air Handling Units. 38AUD 10-12 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 15 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 20 Ton Packaged Air Cooled Condenser Units, Dual …

If you’re in the market for a powerful and reliable workhorse, look no further than one ton trucks. These heavy-duty vehicles are designed to handle the toughest jobs with ease, ma...Carrier 48FC 4 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208-230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;d1049ui2fjityy.cloudfront.net

48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged … CE - Carrier Enterprise

3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-1 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A3-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; BTU Input 90000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial;Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw … Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...

We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...

SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain

Exceeded Department of Energy Advanced RTU Challenge by 15%; Exceeds ASHRAE 90.1 and Energy Star efficiency levels, as well as Consortium for Energy Efficiency (CEE) criteria; 3 to 5 ton models have two-stage cooling capacity control and 6 to 23 ton models have three-stage cooling capacity control; Up to 17.5 SEER and 20.8 IEERBrand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input 250000; Compressor Stage 1; Equipment Type Commercial Packaged …04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerWhen it comes to selecting a fifth wheel, there are many factors to consider. With so many different models and features available, it can be difficult to decide which one is right...These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1 IEER …Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4.Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.

View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A …When it comes to selecting a fifth wheel, there are many factors to consider. With so many different models and features available, it can be difficult to decide which one is right...WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details. carrier chiller data. Check Details. Three Carrier HVAC Units Named Finalists in Consulting-Specifying. Check Details. Carrier 48TCED Manuals | … New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ...Carrier

12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000;

View and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ...If you’re in the market for a powerful and reliable workhorse, look no further than one ton trucks. These heavy-duty vehicles are designed to handle the toughest jobs with ease, ma...Carrier West Training – HVAC TrainingUp to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;Carrier contractors are ready to help you create your ideal home environment. Find an Expertkeyboard_arrow_right. Explore HVAC Systems & Products. Learn about our innovative products and how they can help improve your comfort. Browse Productskeyboard_arrow_right. Learn Heating & Cooling Basics.Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated withFeatures. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 and Energy Star compliant. Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82% Standard cooling operating …

ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.

48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 = Direct Drive, Eco Blue, Medium Static Option A = Al/Cu - Al/Cu 5 = 208/230-3-60 0 = Electro-mechanical Controls can be used with W7212 A = No Air Intake or Exhaust 0 = No Convenience Options A = No ...

Specification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: …Carrier West Training – HVAC Training 48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files. The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:A short ton is equal to 2,000 pounds and a long ton is 2,240 pounds. However, there are different types of tons, depending on the country. In the United States, the ton most common...Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB. CE - carrierenterprise.com 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for …We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...High Altitude Conversion Kit (LP), 3-15 Ton. Item. CRLPELEV003A00. Please Login or Register to view pricing and inventory. Skip to the end of the images gallery ... CARRIER MODELS Check positions 7-8 on unit data plate for unit size. MODEL / UNIT SIZES / NOMINAL TONS 48FC / 04-07 / 3-6 48GC / 04-06 / 3-5 48TC / 08-16 / 7.5-15 48HC / 07 …1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available ... Specification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: … New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Instagram:https://instagram. beaute nails planotaylor swift foxborough seating chartides process timelinelittle caesars arena concert capacity There are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect... juanita tolliver salarymovie times santa clara Carrier3 UNIT ARRANGEMENT AND ACCESS General Figures 1 and 2 show the general unit arrangement and access locations. Fig. 1 — Access Panels and Components, Front Fig. 2 — Typical Access Panel Locations, Rear Routine Maintenance cheats pokemon gba With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ... View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air …InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...