Mcquay model number tonnage.

A ton of air conditioning equals 12,000 BTU's so, for example a “24” in the middle of the model number indicates that it is a 2-ton system, a “30” means 2-1/2 tons, and the “42” in the middle of the model number at the top of the page means the system is 3-1/2 tons. Here’s a few more examples: Trane - 4TWR3030A1000AA - 2-1/2 tons

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

When you need OEM parts or generic parts to repair your HVAC system, you need them quickly. Daikin Service has an expansive inventory and a centralized distribution center to get the right parts to you faster than ever before. To mitigate downtime, we have 80 locations (and counting) across North America and Canada to help you take care of your ...Model Number. WCAE= Concealed Ceiling WSHP, Alerton control, Extended Range. WCAS= Concealed Ceiling WSHP, Alerton control, Standard Range. ... Please contact …Serial Number- February, 1999 and later. AUB U 99 05 00148. Plant Identification Abbreviation. AUB = Auburn. U= Unit. Serial Number (build sequence) Week of Manufacture. Year of Manufacture. 08= 2008. 09= 2009 etc. WSHP; WCAX1,2, WCDX1,2, WCMS1,2 Size 019 Designs A, B Rev. J 01/16 RPL 1105106 / Page 4. Nomenclature. Model Number. WCDS 2 019 E Z ...Buick car models come in all shapes and price ranges. See pictures and learn about the specs, features and history of Buick car models. Advertisement Buick models come in all shape...

Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...ner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate On units with a single compressor on each circuit, the com-pressor will include one compressor nameplate. On units that utilize the tandem compressor design, each

Daikin McQuay Path nder Air Cooled Chiller Screw Compressor 2 Circuit Model: AWS Sizes: 280- 350 Vintage: A R134a 50 Hz Replacement Parts List No. 700014200 New 08/09 To nd your McQuay parts distributor, call 1-800-377-2787 or visit www .mcquay. com

From Table 1, select an ethylene glycol concentration of 40% to protect against freezing at -18°C. At 40% ethylene glycol, the adjustment factors are: Capacity = 0.961, kW = 0.976, GPM = 1.121, pressure drop = 1.263. Select the AGR 070AS and correct with 40% ethylene glycol factors. Correct capacity = 0.961 X 241.5 kW = 232.1 kW.McQuay Enfinity™ water source heat pumps incorporate the best of our past and the best of what's new. Using feed-back from building owners, consulting engineers, contrac- ... Model CCH (Standard Range - 55°F to 110°F) Model CCW (Extended Range/Geothermal - 25°F to 110°F) Vertical (Floor) Water Source Heat Part Number: 910131165. Date: May 2012. IM 1049-3. Daikin McQuay ® Enfinity ™ Horizontal Water Source Heat Pumps R-410A Refrigerant. Model CCH, CCW Unit Sizes 007 – 070 ©2012 McQuay International • 800.432.1342 • www.daikinmcquay.com MODEL CODE A C Z XXX B " Air-Cooled Condensing Unit Scroll Compressor Vinta ge Nominal Tons ©2007 McQuay International. Illustrations and data cover the McQuay International product at the time of publication and we reserve the right to make changes in design and construction at anytime without notice. ™® The following are trademarks or

Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.

Equipment Description. Used McQuay ACR070A827-ER10 Air Cooled Water Chiller with: Air cooled water chiller unit. Maximum relief pressure: 450 PSIG. High side design pressure: 450 PSIG. Low side design pressure: 150 PSIG. Refrigerant: 22. Total charge: 20 pounds. Circuit 1 charge: 60 pounds.

38 Motor Model - FG50A FG50A FN150B FN150B 39 Motor Type - AC AC AC AC 40 Motor Insulation Class - B B B B 41 Motor Safe Class - IP20 IP20 IP20 IP20 42 Overload Protector - N/A N/A N/A N/A 43 Motor Full Load Amp(FLA) A 0.65 0.65 1.6 1.6 44 Fan Motor Drive Type - Direct Direct Direct DirectThis supplement only applies to RGS180 units when there is "B" in the 9th position of the Model Number, as shown in the Model Number Nomenclature diagram below. Check the Unit Nameplate (see Figs. 1 & 2). If there is not a "B" in the 9th position of the model number discard this document. MODEL NOMENCLATURE MODEL SERIES R G S 1 8 0 H F ...1990 Snyder General / McQuay Air cooled Chiller 125 Tons. Model ALRC125C. S/N 5VJ0178900. Refrigerated System. (4) 35 hp Compressors, 56 RLA, 283 LRA (EA), 460 V, 60 Hz, 3 phase, (12) Cond. Fan Motor. 1 hp, 2.0/5.6 Fla, 9.9/14.5 LRA, 230/460 V, 60 Hz, 1 phase, (4) Crankcase HTRS. 0.87 A, 115 V, 60 Hz, 1 phase. ... Snyder General / McQuay Air ...60Hz SEER10 R410A Cooling Only. Notes: The cooling condition: T1 condition: indoor side 27°C (80.6°F) DB, 19°C (60°F) WB, outdoor side 35°C (95°F) DB; The heating condition: indoor side 20°C (68°F) DB, 15°C (44.6°F) WB, outdoor side 7°C (42.8°F) DB. Sound level: measured at a point 1m in front of the unit at a height of 1.3m.For example, if you see numbers like 18, 24, 30, etc., these may indicate the capacity in thousands of BTUs. We will explain below how to easily decode the tonnage of your AC from these numbers. 2. Check for a series of letters or digits. Some manufacturers include a series of letters or digits in the model number that represents the tonnage.Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...Page 5: Added Serial Number Nomenclature section. Page 6- 8: Added Unit Code Index section. Page 9: Added Coil Section. Page 11: Changed footnote #1 to: "Part numbers ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information so the needed part(s) can becorrectlyidentified."

be seen that a Model MC216 UI1it will deliver 6550 CFM with a fan outlet velocity of 1605 FPM and that the cooling coil face velocity will be 500 FPM. 2. From the General Specifications Table on Page 11 it is found that the maximum number of zones is 12 for a Model MC216 unit. Each available zone in a McQuay Multi-Zone unitThese are generally specific use (built to order) and the model number has many more digits/letters. Mcquay is now Daikin. Here is a manual with the model number nomenclature starting on page 5. The actual tons is not listed until position 43. ... Hello, I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller ...Resetting Cooling and Heating Lockouts. 25. Maintenance. 27. Warranty. 29. Advertisement. Trane TTA180C series Pdf User Manuals. View online or download Trane TTA180C series Installation Operation & Maintenance. get special offers & news from parts town. I Want In. 800.438.8898. Parts Town has the largest in-stock inventory of genuine OEM McQuay parts with fast same day shipping until 9pm ET. Find the part you need today. Ford cars come in all shapes and price ranges. See pictures and learn about the specs, features and history of Ford car models. Advertisement Ford models come in all shapes and pri...

R-123 requires about 6 times the gas flow rate (cfm/ton) of R- 134a, which means that the suction and discharge piping must also be six times larger. Using R-134a allows McQuay to provide you with a smaller footprint chiller. Table 1: Centrifugal Models & Possible Applications Application McQuay Model

McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.Buying a HDTV is hard enough with so many different manufactures, model numbers, and sizes, to make things a little easier we've put together a list of the most common specificatio...Page 36 3-1/2 x No. of DX rows *DX coil configuration (S = Standard, L = Large) is identified by the 8th digit of the RPS/RDT or RFS model number, found on the unit nameplate. For example, DX = L for unit model number RFSO6OCLY. Page 37: Refrigeration Service Valves The unit is shipped with all refrigeration service valves closed.ISASecure CSA certification of the YORK® YMC² Centrifugal Chillers exemplifies Johnson Controls leadership in bringing cyber-resilient solutions to the smart buildings market. Certification to the ISA/IEC 62443-4-2 standard provides assurance that Johnson Controls and the YORK® brand adhere to stringent ISASecure technical security ...Part Number: 668996503. Date: November 2011. IM 930-3 ©2011 McQuay International ® Page 2 of 32 / IM 930-3. Model Nomenclature Vertical Floor Unit (Size *007 - 070) NOTE: For illustration purposes only. Not all options available with all models. Please consult McQuay Sales Representative for specific availability.The optimum model can be selected from an extensive product lineup for medium- to large-scale facilities for use in a variety of applications. Versatility. Daikin delivers energy efficiency to a wide range of process cooling applications with a lineup featuring a full range of capacities for all conditions and cooling requirements. ...

Look for the 7th and 8th digits, or 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 42 divided by 12 equals 3.5, so the data plate below indicates the system is 3-1/2 tons.

Engineered HVAC Solutions for Alaska - Stinebaugh & Company

McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of Overview. Positive pressure design with R-134a refrigerant which has no ozone depletion potential and no phase- out schedule. Smallest footprint per ton in the industry to optimize equipment room space. The exclusive movable diffuser geometry design avoids the potential for a surge. Quiet compressor design with unique refrigerant injection ... 38 Motor Model - FG50A FG50A FN150B FN150B 39 Motor Type - AC AC AC AC 40 Motor Insulation Class - B B B B 41 Motor Safe Class - IP20 IP20 IP20 IP20 42 Overload Protector - N/A N/A N/A N/A 43 Motor Full Load Amp(FLA) A 0.65 0.65 1.6 1.6 44 Fan Motor Drive Type - Direct Direct Direct DirectThis number represents the BTUs your unit puts out. To get the tonnage, simply divide the number by 12. If you see the number 18, for example, divide by 12 to get a rating of 1.5 tons. Unfortunately, not every manufacturer does this. If you can't find the tonnage hidden in the model number, write it down and search for it online.Model Type of Document; 1: McQuay HSC Manuals: McQuay Controller HSC Operating manual (100 pages) 2: McQuay IM 702-3 Manuals: McQuay Controller IM 702-3 Installation and maintenance manual (18 pages) 3: McQuay MicroTech Manuals: McQuay Controller MicroTech Installation and maintenance data (10 pages)McQuay Style 1: The Date of Manufacture is in the fifth through eighth digits of the serial number and represents the year and week of production: AUB U 08 05 00396. AUB U 08 05 00396. 08 Year. 05 Week . Style 2: The Date of Manufacture is in the second through third digits of the serial number and represents the year and month of production ...The entire "Model Number" blank on the nameplate reads: "YKKKKLH9-CVF". The unit is a centrifugal chiller, 460 volt, has a VFD drive, the compressor model is "YDHE-70VDD", and the serial number is "SASM-435150". ... Hello, I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller. The SN is STNU020400172.These are generally specific use (built to order) and the model number has many more digits/letters. Mcquay is now Daikin. Here is a manual with the model number nomenclature starting on page 5. The actual tons is not listed until position 43. ... Hello, I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller ...

Available from 600 to 2500 tons, dual compressor chillers offer excellent full-load and part-load performance for increased energy savings. This industrial chiller occupies less floor space than having multiple single compressor chillers, while delivering the equivalent combined capacities. Using R-134a or R-513A refrigerant, these chillers ...Evaporator Model Number CE 063 J AY 18 R Motor HP (X10) Impeller Type: J or K Impeller Size:060= 6.0" 063= 6.3" Gear Ratio (see Gears table for list) Compressor Model Number Compressor Type: CE= Centrifugal Hermetic PE 200 Unit Model Number Unit Type: PE- a single compressor, hermetic centrifugal chiller. Nominal Tonnage Unit …Document Number: Catalog ACZ-AGZB1 Issued: October 2007 Replaces: CAT ACZ-4, CAT AGZ-7 ... Model ACZ 033, 30-ton Condensing Unit . Catalog ACZ-AGZB1 5 Design Features The McQuay air-cooled, scroll compressor units are a product of the McQuay commitment to offer quiet, reliable, energy efficient equipment. These units incorporate high quality ...Instagram:https://instagram. adamskeegan efficenterparker schnabel carbradley funeral home in luraylb to oz calculator McQuay Air Cooled Water Chiller- 220 Ton. Model ALS220A, S/N 56K8146201. (2) Compressors. Refrigerant: R 22. Overall dimensions: 356 in. L x 84 in. W x 95 in. H.View and Download McQuay Vision CA Series installation and maintenance manual online. Vision CA Series air handlers pdf manual download. ... Air handler models oac/oah … botw where is nottsoreillys auto parts livingston texas Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ... cookie plug sacramento General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). The subbase for the Suite II series hydronic heat model is 8" high with a front air intake grille. Leveling legs are supplied with each subbase that allow for an additional 1" adjustment. The standard subbase requires a minimum of 4-3 /8" from the front edge of the wall sleeve to the finished wall.View and Download McQuay ALR 110F product manual online. Air-Cooled Reciprocating Water Chillers, 110 to 150 Tons, 380 to 525 kW, R-22, 60 Hertz. ALR 110F chiller pdf manual download. Also for: Alr 120f, Alr 140f, Alr 130f, Alr 135f, Alr 145f, Alr 150f.